TROUBLE
POSSIBLE CAUSE
REMEDY
14.Oil level drops
quickly
Leakage in the
lubricating circuit
Check the plant and
look for leakage,
replace gaskets, tighten
joints, replace the oil
cooler
15.White foam in the
lubricating oil
Water into the oil Stop the machine for
at least 1 hour and drain
water from lowest point
(Section 4 –
MAINTENANCE)
Water in the oil
because of broken oil
cooler
Pressure check the oil
cooler and replace
Excess of water on
the plungers
Adjust the water flow
to reduce splashing and
sump flooding
16. Oil overheats and
darkens
Machine overload Eliminate overload
Faulty oil cooler or
lack of cooling water
Check the oil cooler
and the water flow
Worn out bearings Contact NIRO SOAVI
17.No oil flow and
pressure
Wrong oil pump
rotation
Change the direction
of rotation of the oil
pump (Section 2 –
GENARAL
INFORMATION)
Failure of the oil pump Contact NIRO SOAVI
3C001E0C.DOC 3.8.6