Niro Soavi S.p.A
TROUBLE
POSSIBLE CAUSE
REMEDY
18.Not enough oil
pressure and
intervention of pressure
switch
Leakage on the
lubricating circuit
Check the oil circuit,
replace gaskets and
tighten joints
Low oil level Restore correct oil
level
Worn out sliding
bearings or crankshaft
Contact NIRO SOAVI
Faulty pressure switch Check the pressure
switch and in case
replace; contact NIRO
SOAVI
Leaking oil cooler Check and replace;
contact NIRO SOAVI
19. Main motor
overload
Too high
homogenizing pressure
Reduce to nominal
value
Wear on drive end Check wear and
contact NIRO SOAVI
Too high belts tension Check belts tension
Faulty main motor Check main motor; in
case replace
20.Oil leakage in the
water sump
Leakage from
crossheads seals
Replace gaskets
(Section 4 –
MAINTENANCE)
Scratched crosshead
extensions
Replace (contact
NIRO SOAVI)
3C001E0C.DOC 3.8.7

Table of Contents