Error Messages 65
Error Cause Remedy
“CAN'T MOVE THE ATC DISK
TO NEW LOCATION”
ATC position movement
sensor did not get activated.
Check sensors and wiring.
Check disk motor and
wiring.
“can't close the door”
“can't engage safety”
“can't grab”
“can't move arm in”
“can't move arm out”
“can't open door”
“can't release tool”
“can't send speed request”
“can't spin disk”
“can't stop spindle”
“can't turn on cone”
“can't undo safety”
“can't w84 grab”
“can't w84 release”
Communication lost with ATC
controller.
Check wiring.
Power cycle tower.
“**Clamp Grab Error!”
“**Clamp Release Error!”
Clamp/unclamp detection
sensor did not activate when
expected.
Check spindle clamp
sensor/wiring.
“E2 NOT FOUND ERROR”
Not used Not used
“E2 NOT WORKING”
Failure in nonvolatile memory. Return processor board for
repair.
“E2 TYPE COULD NOT BE
DETERMINED VALUES WILL
NOT BE SAVED”
Failure in nonvolatile memory
– could not identify the type of
non-volatile memory.
Return processor board for
repair.
“E2 WEAR OUT WARNING
the system will not be able
to save it's settings.”
Failure in nonvolatile memory
– could not write to
nonvolatile memory.
Return processor board for
repair.
“ENCODER NOT ZERO”
X, Y, or Z position encoder is
not properly initialized at
power-up.
Check encoders.
“ERROR: can't talk to the
ATC Controller!”
Communication lost with ATC
controller.
(This may occur even on non-
ATC jobs because ATC is used
to obtain spindle status).
Check wiring. Power cycle
tower.
“ERROR: Interrupt N”
An Interrupt occurred that the
firmware can’t handle.
Interrupt ID is
N
.
Check processor board for
hardware problems.
“ERROR: Invalid code X”
Illegal G-Code command
received.
Verify job type is G-Code
and not “Gerber”.
Use only supported G-codes.
“ERROR: Spindle speed
change failure”
Not used. Not used.