5-21
6
Press the [2] key (SCAN).
Following message is displayed.
7
Press the POSITION (
) keys and move the tool
carriage to the area to start scanning of the registration mark.
Feed direction of media
Align the tool to this area
Registration mark scan area
Supplement
It will return to ARMS SETTING screen (3/4)
without plotting when you press the [ESC] key
(CANCEL).
8
Conrm the position of the tool, and if it is OK, press the
[ENTER] key.
The registration mark for comparison is plotted after scanning the
registration mark (see below). It will return to SENSOR OFFSET ADJ.
screen once the plotting is completed.
Feed direction of media
Distance adjustment value Y
Distance
adjustment
value X
Registration mark for
adjustment
Registration mark
for comparison
Supplement
Position of the registration mark is measured at
the center of the line.
9
Using the scanned registration mark for adjusting, measure
the distance of how much the comparison registration mark
needs to be moved so both will overlap, and record the
value. As an example, in the gure above, it needs to move
in negative directions for both X and Y directions, so both of
the adjustment values will be a negative values.
10
Press the [3] key (X).
SENSOR OFFSET ADJ. X screen is displayed.