15-7
Error Messages in HP-GL Command Mode
If any of the following command errors occur, they are nearly always caused by following 2 reasons.
1. The conguration regarding the output device in the application software has changed.
2. The plotter's interface conditions have changed.
Perform following if these are the cause of the problem.
1. Recongure the output device of the application software to the plotter.
2. Recongure the plotter's interface conditions.
Error
Displayed
LCD Display Cause Solution
E03001
Error 1
An unrecognizable instruction was
executed.
Execute a recognizable command.
E03002
Error 2
Wrong number of parameters were
specied.
Execute the command with the correct
number of parameters.
E03003
Error 3
An unusable parameter was executed. Execute a recognizable parameter.
E03005
Error 5
An unusable character set was specied. Specify usable character set.
E03006
Error 6
Coordinates of command specied out of
cutting area.
Execute coordinates within the cutting area.
E03007
Error 7
The data being input exceeds the capacity
of the plotter's downloadable character
buffer, polygon buffer, etc.
Adjust the buffer size.
E03010
Error 10
Other output command was executed while
executing an output command.
Check the program.
E03011
Error 11
An invalid byte was received after ESC
code.
Check the program.
E03012
Error 12
Invalid byte was received within device
control command.
Check the program.