15-9
ARMS Error Messages
Error
Displayed
LCD Display Cause Solution
E04001 Tilt to adjust with AXIS ALIGNMENT is too
large.
Reload the media.
E04004 It is over the setting range of the distance
adjust.
Reset to smaller value.
E04005 Could not scan the registration marks. Check the registration scan position.
E04006 Amount of data has exceeded the I/O
buffer size for the segment area registration
mark.
Decrease the data.
E04007 Test pattern plotting position is not within
the plotting area for sensor position
adjustment.
Move the media toward center and plot the
test pattern.
E04008 Media end was detected while detecting
the registration mark.
Check the media. Check the print position
of the registration mark.
E04009 It has exceeded detection area while
detecting the registration mark.
Check the media. Check the print position
of the registration mark.
E04010 It has exceeded detection area while
detecting the registration mark.
Check the media. Check the print position
of the registration mark.
E04011 It has exceeded detection area while
detecting the registration mark.
Check the media. Check the print position
of the registration mark.