2-53
Setting tool No.
Set the tool that is used in each of the tool condition numbers.
Setting range : 1, 3
Operation
1
Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/3) is displayed.
2
Press the POSITION ( ) key.
CONDITION setting screen (2/3) is displayed.
Supplement
It will return to CONDITION setting screen (2/3)
without changing the settings when you press
the [ESC] key (CANCEL).
3
Press the [2] key (ASSIGN TOOL)
ASSIGN TOOL setting screen is displayed.
* Display may vary depending on the selected tool condition number.
4
Press the POSITION (
) keys and select the tool condition
number (CONDITION No.).

Table of Contents