5-25
Setting speed of the registration mark scan
Speed of the tool carriage and media to scan the registration mark is set.
It may not scan the registration marks or the difference may become large when the speed is too high, but the
cutting time becomes longer when the speed is too slow. Adjust the setting value considering the balance.
If the registration mark cannot be scanned or the error is large, setting a low (slower) value may improve the
scanning.
Operation
Supplement
Perform the settings in Normal mode.
1
Press the [PAUSE/MENU] key.
MENU screen is displayed.
2
Press the [2] key (ARMS).
ARMS SETTING screen (1/3) is displayed.
3
Press the POSITION ( ) key.
ARMS SETTING screen (2/3) is displayed.
Supplement
It will return to ARMS SETTING screen (2/3)
without changing the settings when you press
the [ESC] key (CANCEL).
4
Press the [3] key (SENSING SPEED).
SENSING SPEED screen is displayed.
Supplement
You can set the range between 1 and 30 (cm/s).
5
Press the POSITION ( ) keys and increase or decrease the
setting value.