EasyManua.ls Logo

GRAPHTEC CE7000 Series - 7.4 Distance Adjustment

GRAPHTEC CE7000 Series
354 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-12
7. 4
Setting the Distance Adjust
DISTANCE ADJUST value corrects any deviation in the length of cut or plotted line segments, which occurs
depending on the media being used. DISTANCE ADJUST value for the deviation is specied as a percentage of
the total distance. For example, a setting of +0.05% adjusts a distance of 2 m (2,000 mm) by 2,000 x 0.05% = 1
mm, making 2,001 mm. DISTANCE ADJUST can be specied for each CONDITION No.
Supplement
This setting will be saved even if the power is shut off.
Operation
Supplement
Perform the settings in Normal mode.
1
Press the [COND/TEST] key.
CONDITION setting screen (1/3) is displayed.
2
Press the POSITION ( ) key.
CONDITION setting screen (3/3) is displayed.
3
Press the [1] key (DISTANCE ADJUST).
D. ADJ. screen is displayed.
4
Press the POSITION (
) keys and select the CONDITION
No.

Table of Contents