3-8
Chapter 3 Cutting along Printed Data
Automatic Registration Mark Position Detection
The area of "A" is scanned from the registration mark scan starting position (position of the tool), and if a
registration mark is not located in the area of "A", the area of "B" is scanned.
Registration marks can be recognized as registration marks if they exist within the areas of "A" or "B".
100100
100
AA
B
B
100
Registration Mark
ScanStarting Position
Media Transport Direction
It may be difcult to scan registration marks depending on the state of the media being used.
Transparent media
Media with blurry printed registration marks
Bent media
Media with a dirty surface
Media having a thickness of 0.6 mm or more
Laminated media (depending on the type and state of lamination)
Media on which black registrations mark lines are not printed on a white surface.
When using media on which black registrations mark lines are not printed on a white surface, set AUTO MARK
SCAN to OFF. (Refer to "Setting Automatic Registration Mark Position Detection")
Otherwise, congure the registration mark scan settings. (Refer to "5.6 Registration Mark Scan Settings")