2-26
z After completing the above configuration, you can execute the cluster switch-to
{ member-number | mac-address H-H-H } command on the management device to switch to
member device view to maintain and manage a member device. After that, you can execute the
cluster switch-to administrator command to return to management device view.
z In addition, you can execute the reboot member { member-number | mac-address H-H-H }
[ eraseflash ] command on the management device to reboot a member device. For detailed
information about these operations, refer to the preceding description in this chapter.
z After the above configuration, you can receive logs and SNMP trap messages of all cluster
members on the NMS.
Enhanced Cluster Feature Configuration Example
Network requirements
z The cluster operates properly.
z Add the device with the MAC address 0001-2034-a0e5 to the cluster blacklist, that is, prevent the
device from being managed and maintained by the cluster.
z Save the current cluster topology as the base topology and save it in the flash of the local
management device in the cluster.
Network diagram
Figure 2-5 Network diagram for the enhanced cluster feature configuration
Configuration procedure
# Enter cluster view.
<aaa_0.Sysname> system-view