2-3
With the history data management function, you can configure network devices to collect history
data, sample and store data of a specific port periodically.
5. Statistics group
Statistics group contains the statistics of each monitored port on a switch. An entry in a statistics
group is an accumulated value counting from the time when the statistics group is created.
The statistics include the number of the following items: collisions, packets with Cyclic
Redundancy Check (CRC) errors, undersize (or oversize) packets, broadcast packets, multicast
packets, and received bytes and packets.
With the RMON statistics management function, you can monitor the use of a port and make
statistics on the errors occurred when the ports are being used.
2.2 RMON Configuration
Before performing RMON configuration, make sure the SNMP agents are correctly configured. For
the information about SNMP agent configuration, refer to section
Configuring Basic SNMP
Functions
.
Follow these steps to configure RMON:
To do… Use the command… Remarks
Enter system view
system-view
Add an event entry
rmon event
event-entry
[
description
string
]
{
log
|
trap
trap
-
community
|
log
-
trap
log
-
trapcommunity |
none
} [
owner
text
]
Optional
Add an alarm entry
rmon alarm
entry
-
number alarm
-
variable
sampling
-
time
{
delta
|
absolute
}
rising_threshold
threshold
-
value1
event
-
entry1
falling_threshold
threshold
-
value2
event
-
entry2
[
owner
text
]
Optional
Before adding an alarm entry,
you need to use the
rmon event
command to define the event to
be referenced by the alarm
entry.
Add an extended
alarm entry
rmon prialarm
entry-number prialarm-formula
prialarm-des sampling-timer
{
delta
|
absolute
|
changeratio
}
rising_threshold
threshold-value1 event-entry1
falling_threshold
threshold-value2 event-entry2
entrytype
{
forever
|
cycle
cycle-period
} [
owner
text
]
Optional
Before adding an extended
alarm entry, you need to use
the
rmon event
command to
define the event to be
referenced by the extended
alarm entry.
Enter Ethernet port
view
interface
interface-type
interface-number
Add a history entry
rmon history
entry
-
number
buckets
number
interval
sampling
-
interval
[
owner
text
]
Optional
Add a statistics
entry
rmon statistics
entry
-
number
[
owner
text
] Optional