19
99 102
87 90
85 91
76 81
Saw-Spindle Moulder
B3 / B3 e-classic
4.6 Noise emission
The specified values are emission values and therefore
do not represent safe workplace values. Even though a
relationship exists between particle emission and noise
emission levels, an inference cannot be made about
whether additional safety measures need to be imple-
mented. Factors which can significantly affect the emis-
sion level that presently exists at the workplace include
duration of the effect, characteristics of the workspace,
and other ambient influences. The permissible workplace
values may also differ from country to country. Neverthe-
less, this information is provided to help the operator bet-
ter assess hazards and risks. Depending on the location
of the machine and other specific conditions, the actual
noise emission values may deviate significantly from the
specified values.
Note:
To keep the noise emission as low as possible, always use sharpened tools and operate the machine at the
correct speed.
Ear protection must always be worn; however, such protection cannot be considered a substitute for properly
sharpened tools.
All values in dB(A) and with a measurement uncertainty factor of 4 dB(A).
Saw unit Idle Working
Sound power level
(EN ISO 3746)
Workplace emissions values
(EN ISO 11202)
Spindle moulder unit Idle Working
Sound power level
(EN ISO 3746)
Workplace emissions values
(EN ISO 11202)
4.5 Particle emission
The machine was tested for particle emissions according
to DIN 33893. The Wood Authority ascertained, accor-
ding to the „Principles for Testing Particle Emissions“
(workplace-related particle concentrations) of woodwor-
king machines, that the particle emission values for this
machine are notably below the currently valid atmosphe-
ric limit of 2.0 mg/m³. This is certified by the blue label
„BG Wood Particle Tested“.
Specifications