Chapter 8 Hardware Reference
© 2017 Harmonic Inc. All rights reserved. 279 Harmonic MediaGrid Release 4.1
Power and Cooling Specifications
Figure 8–61: Rear View of 5406 Network Switch
For more information about the switches, including LED and port descriptions, refer to the
documentation that ships with the product.
IMPORTANT: Hot swapping of the cl modules is not supported on the 1010 switches. A switch reset
occurs if you install or remove modules after the switch has been powered on. Only install or remove
modules during scheduled downtime.
IMPORTANT: The ContentServer 3000/4000 series cannot be connected directly to CX4 ports.
Power and Cooling Specifications
Note the following power and cooling specifications for Harmonic MediaGrid devices.
Table 8–56: Power and Cooling Specifications
Device Input Power Cooling
ContentServer 1042B 100-240V, 60-50Hz 798 BTU/hr @ 234 W
ContentServer 2124A 100-240V, 60-50Hz 1433 BTU/hr @ 420 W
ContentBridge 1000B 100-240V, 60-50Hz 558 BTU/hr @ 164 W
ContentBridge 2010E
100-240V, 60-50Hz 797 BTU/hr @ 234 W
ContentBridge 2010F 100-240V, 60-50Hz 900 BTU/hr @ 264 W
ContentDirector 1000E and 2000B 100-240V, 60-50Hz 797 BTU/hr @ 234 W
ContentDirector 1000F and 2000C 100-240V, 60-50Hz 900 BTU/hr @ 264 W
ContentServer 3000 100-240V, 60-50Hz 2912 BTU/hr @ 854 W
ContentServer 4000 100-240V, 60-50Hz 3047 BTU/hr @ 893 W