EasyManua.ls Logo

Harmonic ProView PVR 6000 Series - Page 258

Harmonic ProView PVR 6000 Series
269 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual
Appendix B
IP-Front End Software Upgrade Procedure
Page B-2 (Rev. 4.1/ SW v1.60/ December 2006)
10. In the Telnet prompt window, type ‘telnet <unit IP Address> 1023’ (use the
same IP Address as in step 9).
11. Type 'exit' and then Enter.
12. Type ' burn “vxw” ' and then Enter.
13. Type ' “burn “ird” ' and then Enter.
14. Power off the PVR 6000.
15. After a few seconds, power on the PVR 6000.
16. On the PVR 6000 front panel, go to Configuration
Æ
Stream
Æ
Source and
select FRONT END (IP)
17. Verify the correct upgrading of the new SW version by going in the PVR
6000 front panel to
Status
Æ
Receiver
Æ
General and checking the SW Version
dd/mm/yy mj.mn
parameter value
NOTE
If power failure occurs during upgrade, repeat the upgrade from step 1

Table of Contents