Page 2-14 (Rev. 4.1/ SW v1.60/ December 2006)
2.5.2. Powering Up
When powering up the PVR 6000 and the receiver is not tuned, expect one of
the following warnings:
Front-End warning – Demodulator not sync
Bit Stream warning – No sync – 0x47 detected
Bit Stream warning – PSI not detected
In case the PVR 6000 warning LED is lit orange, the operator must perform the
following:
Tune or configure the PVR 6000 device
Select a service from the input stream
When the PVR 6000 is correctly configured, “All OK” is displayed and both LEDs
are lit green.
NOTE
Prior to initialization, review Chapter 4-Operation and Management, for how to
use and navigate through the menus and for information on configuration
parameters.
2.5.3. Tuning
The PVR 6000 receiver must be configured to receive a transport stream. For
details about an PVR 6000 device with a DVB-S receiver module, see Section
4.2.2. For details about an PVR 6000 device with an MPEG-over-IP front-end
module, see Section
4.2.2.4.