10/6/10 888-2629-200 3-5
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Maxiva ULX COFDM Series
Figure 3-3 Global Display Header
The second line of the display has operational and status information including:
a. ON, Standby, Fault OFF, ON/FB (transmitter foldback), PS MUTE, and RF
MUTE status indication.
• ON: Normal operating mode
• Standby: Transmitter turned off manually or remotely
• Fault OFF: Transmitter forced off due to fault condition
• ON/FB: Transmitter power folded back. Conditions causing the foldback
may by temporary and could possibly be cleared by pressing the ON button.
If, after pressing the ON button to reset the foldback, the ON/FB indication
resumes the malfunction will need to be determined and the transmitter
repaired (see Section 6 for fault log listings).
• PS MUTE: A temporary fault condition caused by a power supply related
fault. If underlying fault clears, the mute condition will be lifted and the
transmitter returned to normal operating mode. If the mute continues, the
underlying fault will need to be determined and the transmitter repaired (see
Section 6 for fault log listings).
• RF MUTE: A temporary fault condition caused by an RF related fault. If
underlying fault clears, the mute condition will be lifted and the transmitter
returned to normal operating mode. If the mute continues, the underlying
fault will need to be determined and the transmitter repaired (see Section 6
for fault log listings).
System Forward Power Bargraph
Transmitter Model Number
Fault & Operational
Status
Forward and Reflected
Power Outputs
Reflected Power Bargraph
100% Mark - Based on
Nominal Power Output setting
in System Setup screen