3-6 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Maxiva ULX COFDM Series
b. Transmitter Forward power output reading in numerical format (for multiple
cabinet transmitters this would be a system power reading and not for a single
cabinet). It is important to note that this is the power output after the filter.
c. Transmitter Forward power output reading in a Bargraph format. The 100% mark
is based on the nominal power level or TPO (Transmitter Power Output) entered
into the configuration screen. The bargraph will also turn yellow if the power
level is more than 10% higher or lower than the nominal 100% level.
NOTE:
Indications on the global display header in Figure 3-3 should be all green under
normal (no fault) operating conditions. A yellow or red symbol or status indica-
tion on the global display header should be investigated by the station engineer.