Modules and transducers
96 I3031-14.0 HBM: public Quantum
X
8.2 MX840/A/B universal amplifier
Important
There are three MX840 geerations:
MX840 : 2008 version
MX840A: 2011 version
MX840B: 2015 version
Extended function:
- IEPE transducers and strain gauge bridge with DC
supply
- Decimal rates (switchable)
- Ethernet‐based synchronization via IEEE1588:2008
(PTPv2)
- 40 kS/s sample rate per channel, 7.2 kHz band
width
The MX840B universal amplifier provides 8 channels.
Every channel supports over 15 different transducer
technologies. The pin assignment of the 15pin
DSUB15HD connector with the respective transducer
technology or function is identical for all amplifiers using
DSUB15HD. All measuring channels are electrically
isolated from one another and from the mains. When us
ing the adjustable transducer excitation, electrical isola
tion from the supply voltage of the amplifier is not re
quired.