EasyManuals Logo

Heinzmann PHLOX II IC-08 User Manual

Heinzmann PHLOX II IC-08
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
11 Commissioning
94 PHLOX II Ignition Control System
11.5 Ignition stop
Ignition stops when speed falls below StartSpeed1 (Par. 255)
Additionally, a digital input can be configured as ignition stop command. If that is the case,
depending on Par. 4810, the ignition will stop as soon as the stop command is applied [Par.
4810 = 0] or until the engine stops (speed=0) [Par. 4810 = 1].
Speed
Time
StartSpeed1
Par. 255
Ignition
stop
Ignition
start
StartSpeed2
Par. 256
StartDuration1
Par. 265

Table of Contents