4 PHLOX II control unit, technical data
PHLOX II Ignition Control System 9
4 PHLOX II control unit, technical data
4.1 General
Number of cylinders
- by PHLOX II IC-08 , IC-08A or IC-08B up to 8
- by PHLOX II IC-12 , IC-12A or IC-12B up to 12
- by PHLOX II IC-16 , IC-16A or IC-16B up to 16
Power supply nominal 24 V
DC
range 18 … 32 V
DC
temporarily allowed ( 0.5 s) 9 … 33 V
DC
Current consumption by
24V and 1800 rpm, maximal level of ignition energy
- by PHLOX II IC-08 , IC-08A or IC-08B up to 2,4 A (DC)
- by PHLOX II IC-12 , IC-12A or IC-12B up to 3,5 A (DC)
- by PHLOX II IC-16 , IC-16A or IC-16B up to 4,7 A (DC)
Current-pulse for ~ 5 ms by switching on power supply up to 50 A
External fuse 10 AT / 32 V (DC) C-type
Ambient temperature -40 … +95 °C
Protection grade IP 66
Polution degree 2
Engine speed 30 … 3000 rpm
Spark duration 200 … 600 μs
Energy level 32 levels, 25 … 280 mJ
Peak voltage of primary ignition circuit max. 300 V