14 Error Handling
PHLOX - Ignition Control System 201
14.4.3 Overspeed
3004 ErrOverSpeed
Error
Meaning
0
Overspeed pick-up 1
- Engine speed as registered by pick-up 1 was/is exceeding overspeed.
- A combination between teeth number of pick-up 1 and maximum
speed/overspeed results in a measuring frequency higher than allowed.
Emergency shutdown
Check overspeed parameter (21 SpeedOver).
Check adjustment of set speed.
Check PID adjustment.
Check whether overspeeding was due to thrust operation.
1
Overspeed pick-up 2
- Engine speed as registered by pick-up 2 was/is exceeding overspeed.
- A combination between teeth number of pick-up 2 and maximum
speed/overspeed results in a measuring frequency higher than allowed.
Emergency shutdown
Check overspeed parameter (21 SpeedOver).
Check adjustment of set speed.
Check PID adjustment.
Check whether overspeed was due to thrust operation.
2
Overspeed camshaft index sensor
- Speed of camshaft index sensor was/is exceeding overspeed.
Emergency camshaft wheel: emergency shutdown
Camshaft measuring pin: error message only
Check overspeed parameter (21 SpeedOver).
Check adjustment of set speed.
Check PID adjustment.
Check whether overspeeding was due to thrust operation.
Table 29: Possible errors: Overspeed

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Heinzmann PHLOX II IC-08 and is the answer not in the manual?

Heinzmann PHLOX II IC-08 Specifications

General IconGeneral
BrandHeinzmann
ModelPHLOX II IC-08
CategoryControl Systems
LanguageEnglish

Related product manuals