9 Inputs and outputs
PHLOX II Ignition Control System 55
9.2 Pick-up inputs
Depending on the firmware used, the PHLOX II control unit can make use of 1 or 2
pick-up inputs.
- Firmware with support for 2 pick-ups
0 = pick-up deactivated
1 = pick-up activated
4020 PickUpInductivOrHall
0 = Hall pick-up
1 = inductive pick-up
4021 MeasWheelBoreOrTeeth
Indicates if the measuring wheel
consists of holes or teeth
0 = Teeth
1 = Holes
Only Hall pick-ups (Par. 4020 = 0):
selects the pick-up power supply on
pin 11
0 = 12V
1 = 5V
Only Hall pick-ups (Par. 4020 = 0):
indicates whether the pick-up polar-
ity is similar to Heinzmann pick-ups
or inverted
0 = Hzm standard (low over tooth)
1 = Inverted (low over gap)
Only Hall pick-ups (Par. 4020 = 0):
selects trigger flank used either as
Heinzmann standard or inverse
0 = Hzm standard (the flank used is
the one at the begin of tooth / hole)
1 = Inverse (the flank used is the
one at the end of tooth / hole)
0 = pick-up deactivated
1 = pick-up activated
0 = Hall pick-up
1 = inductive pick-up
Indicates if the cam index is a hole
or a tooth
0 = Tooth
1 = Hole