9 Inputs and outputs
PHLOX II Ignition Control System 53
9 Inputs and outputs
9.1 Selectable inputs/outputs
The PHLOX II control unit is equipped with 2 pick-up inputs, 1 analogue input and 2
selectable digital ports. These can function as input or output, digital or PWM.
Connection
name
Terminal
Configuration
parameters
Configuration
P1
16
4798 DigChannel1_CamIxOut
0 = Normal dig / PWM
In/Out
1 = Cam index digital
output
4800 DigChannel1OutOrIn
If not Cam Ix Out (Par.
4798 = 0)
0 = Input 1
1 = Output 1
4801 DigChannel1PWMOrDIO
0 = Digital input / output
1 = PWM input / output
4802 DigCh1TriStatOrDigIn
If digital input (Par.
4798 = 0, Par. 4800 = 0,
Par. 4801 = 0)
0 = Normal digital input
1 = Tristate switch
4803 DigIn1HighOrLowSide
If digital / PWM input
(Par. 4798 = 0, Par. 4800
= 0, Par. 4801 =1 or Par.
4802 = 0)
0 = Low side input (Pull-
up activated)
1 = High side input
(Pull-down activated)
P2
3
4799 DigChannel2_CamIxOut
0 = Normal dig / PWM
In/Out
1 = Cam index digital
output
4804 DigChannel2OutOrIn
If not Cam Ix Out (Par.
4799 = 0)
0 = Input 2
1 = Output 2
4805 DigChannel2PWMOrDIO
0 = Digital input / output
1 = PWM input / output

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Heinzmann PHLOX II IC-08 and is the answer not in the manual?

Heinzmann PHLOX II IC-08 Specifications

General IconGeneral
BrandHeinzmann
ModelPHLOX II IC-08
CategoryControl Systems
LanguageEnglish

Related product manuals