14 Error Handling
206 PHLOX II Ignition Control System
14.4.9 CAN communication
3071 ErrCanComm1 3072 ErrCanComm2
Error
Meaning
0
Receipt time was exceeded
- Parameter 2403 CanRxTimeout shows with what device type the timeout
has occurred.
Reaction depends on device type.
1
Overflow of receipt buffer
- The receipt buffer has overflown. Some messages could not be received.
Parameter 2402 CanRxBufferState shows on what device type the receipt
buffer has overflown.
only error message
2
Overflow of send buffer
- The send buffer has overflown. Some messages could not be sent. Param-
eter 2401 CanTxBufferState shows on what device type the send buffer
has overflown.
error message only
3
Erroneous device configuration
- Two devices with the same device number and of the same device type
are connected to the CAN network. CAN communication is disabled.
No CAN telegrams are sent or received.
Assign a unique device number in the respective parameter.
Ignition shutdown
Table 35: Possible errors: CAN communication
Supplementary Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Heinzmann PHLOX II IC-08 and is the answer not in the manual?

Heinzmann PHLOX II IC-08 Specifications

General IconGeneral
BrandHeinzmann
ModelPHLOX II IC-08
CategoryControl Systems
LanguageEnglish

Related product manuals