6 Installation
PHLOX II Ignition Control System 27
6.3.3 Digital inputs and outputs
Wires for 2× independent digital indut/outputs:
Terminal 16 (DIO1 - digital In/Out No. 1),
terminal 3 (DIO2 - digital In/Out No. 2)
2 universal terminals for discrete signals, configurable for operating elements such
as switches, actuators, relays, lamps etc.
Each DIOx is configurable as:
- low-side DI,
- high-side DI,
- low-side DO,
- low-side PWM-In,
- low-side PWM-Out
0 V ... +Bat. - Potential
PHLOX wire-terminals in control cabinet and relays, lamps or other ECU.
Wire 1.5 ... 2.5 mm
2
, unshilded
Cable to the control cabinet is part of PHLOX II input cable harness
DIO1-terminal in PWM-output mode is translating PWM=50%;
DIO2-terminal in PWM-input mode is reciving them.
See test arrangement.
Standard actuators and sensors
Other ECU:
digital- or
PWM-input