4 PHLOX II control unit, technical data
PHLOX II Ignition Control System 11
4.3 Communication ports
- CAN-1 communication-protocol CAN2.0B,
protocol SAE J1939, CANopen, DeviceNet,
HEINZMANN CAN
- CAN-2 / Modbus (isolated)
Included in devices PHLOX II IC08A or IC-12A or IC-16A as:
Communication/ protocol CAN2.0B,
protocol SAE J1939, CANopen, DeviceNet,
HEINZMANN CAN
Included in devices PHLOX II IC08B or IC-12B or IC-16B as:
Modbus RTU or additional CAN interface
Configuration tool HZM DcDesk 2000, hand programmer
4.4 PHLOX-II ATEX Certification
All PHLOX ICS-12 /16 and derived systems described in the previous chapters are
ATEX-certified according to EN 60079-0 and EN 60079-15 respectively restricted
breathing protection type "nR".
HEINZMANN will attach the following information sign to the housing:
HEINZMANN GmbH & Co. KG Germany
www.heinzmann.de Tel.: +49 7673 8208-0
Type: P/T-S-01, II3G Ex nA II T4
T
cable
: -5°C to +80°C, T
housing
: -40°C to +130°C
TÜV 07 ATEX 552892X
WARNING - EXPLOSION HAZARD -
DO NOT DISCONNECT WHILE CIRCUIT
IS LIVE UNLESS AREA IS KNOWN
TO BE NON-HAZARDOUS