11
Comm
issioning
104
PHLOX II I
gnition Control System
It
is,
of
course,
possible
to
set
up
a
fix
cylinder
individual
ignition
angle
correction,
which
is
independent
of
speed
or
load.
To
do
thi
s,
delete
the
second
column
and
the
second
di
a-
gram and setup the correction value in the upper left cell, as in the following example:
115
117
Table of Contents
Default Chapter
9
Table of Contents
9
1 Safety Instructions and Related Symbols
13
2 System Description
14
Proper and Intended Use
14
Operational Principle
14
System Components
16
System Characteristics
16
Applications
17
Additional Functions
17
3 Operation, Maintenance and Service
19
4 PHLOX II Control Unit, Technical Data
21
General
21
Dimensional Drawing
22
Communication Ports
23
PHLOX-II ATEX Certification
23
5 Sensors
24
Pick-Up Sensors in General
24
Magnetic Speed Pick-Up IA
25
Technical Data
25
Distance of the Speed Pick-Up
25
Dimensions and Order Information
26
Hall Sensors
27
Boost Pressure Sensor
28
Potentiometer
29
Setpoint Potentiometer SW 02 - 10M, (1 - Turn)
29
Setpoint Potentiometer SW 02 - 10 - K, (10 - Turn)
29
6 Installation
31
Mounting the Control Unit
31
Pin Assignment
33
PHLOX II - IC8/12/16 - Pin Assignment Connector X1
33
PHLOX II - IC8/12/16 - Pin Assignment Connector X2
35
Electric Connections and Requirements for Electric Installation
37
General Requirements for Installation and Use
37
DC Power Supply Terminal End Protoctive Earth
38
Digital Inputs and Outputs
39
Terminals for Shaft Position Pick-Up Sensors
40
Analogue Input
42
And CAN-2 / Modbus Communication Ports
44
Ignition Output for Primary Connection to Ignition Coils
50
Requirements for Installation of HV-Part of Ignition System PHLOX II
53
7 Sensor Configuration
54
Sensor Overview
54
Configuration of Sensors
54
Assigning Inputs to Sensors and Setpoint Adjusters
55
Measuring Ranges of Sensors
56
Modifying Reactions to Sensor Errors
57
8 Switching Functions
59
Complete Overview of All Switching Functions
59
Ignition Stop
60
Assignment of Digital Inputs
60
HZM-CAN Periphery Module
62
Assignment of Communication Modules
63
Value of a Switching Function
63
9 Inputs and Outputs
65
Selectable Inputs/Outputs
65
Pick-Up Inputs
67
Analogue Input
69
PWM Inputs
70
Digital Inputs
70
PWM Outputs
70
Digital Outputs
71
10 Configuring the Control's Inputs and Outputs
72
Digital Inputs
72
Analogue Inputs
72
Calibration of Current/Voltage Inputs
72
Filtering of Analogue Inputs
73
Error Detection in Analogue Inputs
73
Overview of the Parameters Associated with the Analogue Input
75
PWM Inputs
75
Error Detection at PWM Inputs
76
PWM Outputs
76
PWM Output Frequency
76
Assignment of Output Parameters to PWM Outputs
77
Value Range of Output Parameters
78
Value Range of PWM Outputs
79
Error Monitoring of PWM Outputs
79
Digital Outputs
80
Multiple Allocation
81
Error Monitoring of Digital Outputs
83
11 Commissioning
85
Software Versions
85
Engine Configuration
87
Predefined Engine Configurations
87
Manual Engine Configuration
88
Pick-Up Configuration
89
Measuring Method 1 (Software Versions AAA-B1/2-DDD)
90
Measuring Method 2 (Software Version AAA-B1/2-DDD)
97
Measuring Method 3 (Software Version AAA-B0-DDD)
101
Ignition Start
105
Ignition Stop
106
Common Ignition-Based Timing
107
Fix Common Ignition Base Timing
107
Speed- and Load-Dependant Common Ignition Base Timing
108
Common Ignition Timing Offsets
112
Internal Ignition Timing Offset
113
External Ignition Timing Offset
114
Cylinder Individual Ignition Angle Offsets
115
Internal Cylinder Individual Ignition Angle Offsets
115
External Cylinder Specific Knock Retards
117
Ignition Energy
119
Fix Common Ignition Energy Set Point
119
External Common Ignition Energy Set Point Offset
119
Cylinder Specific Ignition Energy Correction
120
Ignition Test
121
Ignition Diagnostics
123
12 Parameter Settings for PHLOX II Control Unit
130
Parameterisation with the Hand Held Programmer 3
130
Parameterisation with the PC / Laptop
130
13 Parameter Description
131
Parameter Overview
131
Parameters
132
Measurements
148
Functions
185
Curves
198
14 Error Handling
203
General
203
Configuration Errors
205
Error Memories
207
Error Parameter List
208
Speed Sensors
210
Camshaft Index Sensor
211
Overspeed
213
Setpoint Adjusters and Sensors
214
Ignition
216
Synchronisation
216
Ignition Shutdown
217
CAN Bus
217
CAN Communication
218
Internal Voltage Measurement
219
Internal Temperature Measurement
222
Data Memory
223
Configuration
224
Internal Computing Error
224
Digital and PWM Outputs
225
Ignition Errors
227
Boot Loader
229
Boot Loader Start Tests
229
Boot Loader Communication with Dcdesk 2000
230
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Heinzmann PHLOX II IC-08 and is the answer not in the manual?
Ask a question
Heinzmann PHLOX II IC-08 Specifications
General
Brand
Heinzmann
Model
PHLOX II IC-08
Category
Control Systems
Language
English
Related product manuals
Heinzmann KRONOS 20
106 pages