13 Parameter Description
PHLOX - Ignition Control System 131
Level: 2
Range: 0 ... 16
Page(s):
Selection of cylinder for click test
Level: 4
Range: -10 ... 90 °BTDC
Page(s):
Fix ignition base timing, common to all cylinders.
Active if Par. 5910 = 0
Level: 4
Range: -30 ... 0 °BTDC
Page(s):
Maximum knock ignition angle offset in °crank correspond-
ing to a spark retard of 100%
Level: 4
Range: -30 ... 30 °BTDC
Page(s):
Minimal digital ignition timing offset
Level: 4
Range: -30 ... 30 °BTDC
Page(s):
Maximal digital ignition timing offset
Level: 4
Range: 0 ... 12 °BTDC
Page(s):
Digital ignition timing offset step for each increase or de-
crease impulse
Level: 4
Range: 0 ... 100 s
Page(s):
Filter value for the ignition energy measurement
Level: 4
Range: 0 ... 31 s
Page(s):
Fix ignition energy set point, common to all cylinders.
Active if Par. 5947 = 0
Level: 4
Range: -31 ... 31 s
Page(s):
Minimum digital ignition energy offset