13 Parameter Description
134 PHLOX II Ignition Control System
Level: 4
Range: -31 ... 31
Page(s):
Cylinder specific Ignition energy set point offset for cylinder
16.
Active if Par. 5950 = 1
Level: 4
Range: 0 ... 100 s
Page(s):
Filter value for the ignition spark duration measurement
Level: 4
Range: 0 ... 1.5 ms
Page(s):
Lower error limit for spark duration
Level: 4
Range: 0 ... 1.5 ms
Page(s):
Upper error limit for spark duration
Level: 6
Range: 0 ... 100 s
Page(s):
Off-time while ignition is suspended on one cylinder if a pri-
mary short condition has been detected
Level: 4
Range: 0 ... 100 s
Page(s):
Delay for secondary diagnostics (secondary short / open,
spark duration too low / high)
Level: 6
Range: 0 ... 2.55 s
Page(s):
Delay for error report at digital / PWM output 2
Level: 6
Range: 0 ... 32
Page(s):
HZM CAN Customer-Module Manual DG 05007-e
Switch assignment to function "Ignition stop" via com-
munication modules
Level: 6
Range: 0 ... 32
Page(s):
HZM CAN Customer-Module Manual DG 05007-e
Switch assignment to function "Ignition Timing Offset
Increase" via communication modules