13 Parameter Description
188 PHLOX II Ignition Control System
Range: 0 ... 4000 1/min
Page(s):
dependent ignition angle correction map of cylinder 1-16
Level: 4
Range: 0,0 ... 200,0 %
Page(s):
Load-supporting points of cylinder specific speed / load de-
pendent ignition angle correction map of cylinder 1-16
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 1
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 2
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 3
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 4
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 5
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 6
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinderr 7
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 8