13 Parameter Description
188 PHLOX II Ignition Control System
17501
Range: 0 ... 4000 1/min
Page(s):
dependent ignition angle correction map of cylinder 1-16
17505
IgnAngCor:Load(x)
up to
17506
Level: 4
Range: 0,0 ... 200,0 %
Page(s):
Load-supporting points of cylinder specific speed / load de-
pendent ignition angle correction map of cylinder 1-16
17510
IgnAngCor1:Angle(x)
up to
17513
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 1
17514
IgnAngCor2:Angle(x)
up to
17517
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 2
17518
IgnAngCor3:Angle(x)
up to
17521
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 3
17522
IgnAngCor4:Angle(x)
up to
17525
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 4
17526
IgnAngCor5:Angle(x)
up to
17529
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 5
17530
IgnAngCor6:Angle(x)
up to
17533
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 6
17534
IgnAngCor7:Angle(x)
up to
17537
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinderr 7
17538
IgnAngCor8:Angle(x)
up to
17541
Level: 4
Range: -12.00 ... 12.00 °crank
Page(s):
Ignition angle correction values of cylinder specific speed /
load-dependent ignition angle correction map - cylinder 8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Heinzmann PHLOX II IC-08 and is the answer not in the manual?

Heinzmann PHLOX II IC-08 Specifications

General IconGeneral
BrandHeinzmann
ModelPHLOX II IC-08
CategoryControl Systems
LanguageEnglish

Related product manuals