Total Station Manual
- 64 -
Steps
Key
Display
1 Press [F3] in the
Pre-Settings screen. Then
enter the Set STA function.
[F3]
[Surveying]
[*] F1 Set Job (1)
[*] F2 Set STA (2)
[ ] F3 Set B.S. (3)
F4 Start (4)
F1 F2 F3 F4
2 Press [F1] and select the
[Angle Setting] to input
orientation manually.
[F1]
[Set B.S.]
F1 Angle Setting (1)
F2 Coordinates (2)
F1 F2
3 Aim B.S. point and then
input the azimuth, prism
height and backsight point
name. Press [ENT] after
finishing every input.
Input
horizontal
angle
+
[ENT]
[Angle Setting]
Azimuth :
T.H. :
BS PT :
Aim BS. Then ALL/REC!
ALL REC Zero EDM
50 °0000
1.500 m
DEFAULT1
4 Press [F1](ALL) to start
measuring and set the
orientation.
[REC]: Press this key to finish
setting orientation without
measurement.
[Zero]: Set the azimuth as 0.
[F1]
BS SET
5 Back to Pre-Settings
screen. The setting items that
have been made are marked
with *.
[Surveying]
[*] F1 Set Job (1)
[*] F2 Set STA (2)
[*] F3 Set B.S. (3)
F4 Start (4)
F1 F2 F3 F4