Total Station Manual
- 77 -
○
2 Press [PAGE] to go to page
1/3(Default page). Press
direction key and move the
cursor to input prism height
item. Input the prism height
and then press [ENT] to
confirm.
[PAGE]
+
↓
+
Input
prism
height
+
[ENT]
*
ALL DIST REC
[Stakeout] 1/3
Search :
Pt. :
T.H :
Hz : ←
: ---
: ---
5
2.000 m
13°39′10″
------
------
○
3 Aim at the prism. Press
[F2](DIST) to start measuring
and calculate the differences
between measured point and
stakeout point.
*
ALL DIST REC
[Stakeout] 1/3
Search :
Pt. :
T.H :
Hz : ←
: ↓
: ↑
5
2.000 m
63°56′37″
2.481 m
-1.331 m
○
4 Turn the instrument
telescope to make the △Hz
equal 0 ° 00 ′ 00 ″ and
command the staff to move
the prism at the same time.
Arrows Meaning:
←:Look forward from station
and move the prism to the
left.
→:Look forward from
statioand move the prism to
the right.
*
ALL DIST REC
[Stakeout] 1/3
Search :
Pt. :
T.H :
Hz : *
: ↓
: ↑
5
2.000 m
0°00′00″
2.534 m
-1.309 m
○
5 While the △ Hz equals
0°00′00″, press [F2](DIST)
to start measuring and
calculate the differences
between measured point and
stakeout point.
The arrow’s direction is the
*
ALL DIST REC
[Stakeout] 1/3
Search :
Pt. :
T.H :
Hz : *
: ↓
: ↑
5
2.000 m
0°00′00″
2.324 m
-0.309 m