Multicasts
101
For “Send Interval” and “Max. Response Time”,
select a large value if you want to reduce the load on your network and
can accept the resulting longer switching times,
select a small value if you require short switching times and can accept
the resulting network load.
Multicasts
In this frame you specify how the device transmits packets with
X unknown MAC/IP Multicast address not learned with IGMP Snooping
X known MAC/IP Multicast address learned with IGMP Snooping.
Prerequisite: The IGMP Snooping function is activated globally.
Parameter Protocol
Version
Value range Default setting
Max. Response Time, 1, 2
3
1-25 seconds
1-3,598 seconds
10 seconds
Send Interval 1, 2, 3 2-3,599 seconds 125 seconds
Group Membership Interval 1, 2, 3 3-3,600 seconds 260 seconds
Table 34: Value range for
- Max. Response Time
- Send Interval
- Group Membership Interval