8.3 Industrial Protocols
The “Industry Protocols” menu allows you to
X configure the PROFINET IO protocol as well as
X the EtherNet/IP protocol.
Detailed information on industrial protocols and PLC configuration is
contained in the User Manual "Industrial Protocols“.
8.3.1 PROFINET IO
This dialog allows you to configure the PROFINET IO protocol. To integrate
this in a control system, perform the following steps.
General settings:
In the Basic Settings:Network dialog, check whether Local is
selected in the “Mode” frame (see on page 24 “Network“).
In the Switching:VLAN:Global dialog, check whether “VLAN 0
Transparent Mode” is selected (see on page 108 “VLAN Global“).
Note: Exclude a combination of the VLAN 0 Transparent mode and the
use of MSTP (Multiple Spanning Tree).
Configure the alarm settings and the threshold values for the alarms you
want to monitor (see on page 254 “Device Status“).
Global PROFINET IO settings:
Switch on the function by selecting “ProfinetIO”.
Click on “Download GSDML File” to load the GSDML file onto your PC.