9.10 Report
The following reports are available for the diagnostics:
X Log file.
The log file is an HTML file in which the device writes important device-
internal events.
X System information.
The system information is an HTML file containing system-relevant data.
Note: You have the option to also send the logged events to one or more
syslog servers (see on page 236 “Syslog“).
The following buttons are available:
X Download Switch-Dump.
This button allows you to download system information as files in a ZIP
archive (see table 112).
Select the directory in which you want to save the switch dump.
Click “Save”.
The device creates the file name of the switch dumps automatically in the
format <IP address>_<system name>.zip, e.g. for a device of the type
PowerMICE: “10.0.1.112_PowerMICE-517A80.zip”.
X Download JAR file.
This button allows you to download the applet of the Web-based interface
as a JAR file. Then you have the option to start the applet outside of a
browser.
This facilitates the device administration even when you have disabled its
web server for security reasons.
Select the directory in which you want to save the applet.
Click “Save”.