EasyManuals Logo

Hirschmann MACH 4000 Reference Manual

Hirschmann MACH 4000
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Basic Settings
RM Web L3E
Release
6.0
07/2010
1.6
Loading/Saving the Configuration
37
Note: Before loading the configuration data from the ACA, the device
compares the password in the device with the password in the ACA
configuration data.
The device loads the configuration data if
X the admin password matches or
X there is no password saved locally or
X the local password is the original default password or
X no configuration is saved locally.
Status Meaning
notPresent No ACA present
ok The configuration data from the ACA and the device
match.
removed The ACA was removed after booting.
notInSync - The configuration data of the ACA and the device do
not match or only one file exists
a
,
or
- no configuration file is present on the ACA or on the
device
b
.
a. In these cases, the ACA status is identical to the status “ACA not in
sync”, which sends “Not OK” to the signal contacts, and the device
status.
b. In this case, the ACA status (“notInSync”) deviates from the status
“ACA not in sync”, which sends “OK” to the signal contacts, and the
device status.
outOfMemory The local configuration data is too extensive to be
stored on the ACA.
wrongMachine The configuration data in the ACA originates from a
different device type and cannot be read or converted.
checksumErr The configuration data is damaged.
Table 3: ACA Status

Table of Contents

Other manuals for Hirschmann MACH 4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 4000 and is the answer not in the manual?

Hirschmann MACH 4000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 4000
CategoryNetwork Router
LanguageEnglish

Related product manuals