Basic Settings
RM Web L3E
Release
 
6.0
 
07/2010
1.6
 
Loading/Saving the Configuration
37
Note: Before loading the configuration data from the ACA, the device 
compares the password in the device with the password in the ACA 
configuration data.
The device loads the configuration data if
X the admin password matches or
X there is no password saved locally or 
X the local password is the original default password or 
X no configuration is saved locally. 
Status Meaning
notPresent No ACA present
ok The configuration data from the ACA and the device 
match.
removed The ACA was removed after booting.
notInSync - The configuration data of the ACA and the device do 
not match or only one file exists
a
, 
or  
- no configuration file is present on the ACA or on the 
device
b
.
a. In these cases, the ACA status is identical to the status “ACA not in 
sync”, which sends “Not OK” to the signal contacts, and the device 
status.
b. In this case, the ACA status (“notInSync”) deviates from the status 
“ACA not in sync”, which sends “OK” to the signal contacts, and the 
device status.
outOfMemory The local configuration data is too extensive to be 
stored on the ACA.
wrongMachine The configuration data in the ACA originates from a 
different device type and cannot be read or converted.
checksumErr The configuration data is damaged.
Table 3: ACA Status