Time
74
3.2
PTP (IEEE 1588)
RM Web
Release
6.0
07/2010
3.2.1 PTP Global (MS20/MS30, PowerMICE,
MACH 104, MACH 1040)
The table below helps you to select the PTP version and the PTP mode.
The PTP modes
- v1-boundary-clock,
- v2-boundary-clock-onestep,
- v2-boundary-clock-twostep and
- v2-transparent-clock
enable you to optimize the accuracy of the time.
You use these dialogs here
X Version 1
X Version 2 (Boundary Clock, BC)
X Version 2 Transparent Clock, (TC)
The PTP modes
- v1-simple-mode and
- v2-simple-mode
allow you to use the plug-and-play start-up.
Version Mode Reference clock
used
Device with
timestamp
PTP messages
Version 1 v1-simple-mode Version 1 No
v1-boundary-clock Version 1 Yes Process
Version 2 v2-simple-mode Version 2 No
v2-boundary-clock-
onestep
Version 2 Yes Process
v2-boundary-clock-
twostep
Version 2 Yes Process
v2-transparent-clock Version 2 Yes Forward
Table 14: Selecting the PTP version and the PTP mode

Table of Contents

Other manuals for Hirschmann MACH 4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 4000 and is the answer not in the manual?

Hirschmann MACH 4000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 4000
CategoryNetwork Router
LanguageEnglish

Related product manuals