Redundancy
RM Web L3E
Release
6.0
07/2010
7.4
Ring/Network Coupling
181
Device Coupling port
RS2-./. Not possible
RS2-16M Adjustable for all ports (default setting: port 1)
RS20, RS30, RS40 Adjustable for all ports (default setting: port 1.4)
OCTOPUS Adjustable for all ports (default setting: port 1.4)
MICE Adjustable for all ports (default setting: port 1.4)
PowerMICE Adjustable for all ports (default setting: port 1.4)
MS20 Adjustable for all ports (default setting: port 1.4)
MS30 Adjustable for all ports (default setting: port 2.4)
RSR20/30 Adjustable for all ports (default setting: port 1.4)
MACH 100 Adjustable for all ports (default setting: port 1.4)
MACH 1000 Adjustable for all ports (default setting: port 1.4)
MACH 3000 Adjustable for all ports
MACH 4000 Adjustable for all ports (default setting: port 1.4)
Table 78: Port assignment for the redundant coupling (two-Switch coupling)
Device Coupling port Control port
RS2-./. Port 1 Stand-by port (can only be combined
with RS2-../.. )
RS2-16M Adjustable for all ports
(default setting: port 1)
Adjustable for all ports
(default setting: port 2)
RS20, RS30,
RS40
Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
OCTOPUS Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MICE Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
PowerMICE Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MS20 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MS30 Adjustable for all ports
(default setting: port 2.4)
Adjustable for all ports
(default setting: port 2.3)
RSR20/RSR30 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MACH 100 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MACH 1000 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
MACH 3000 Adjustable for all ports Adjustable for all ports
MACH 4000 Adjustable for all ports
(default setting: port 1.4)
Adjustable for all ports
(default setting: port 1.3)
Table 79: Port assignment for the redundant coupling (two-Switch coupling with
control line)