Redundancy
RM Web L3E
Release
6.0
07/2010
7.5
Spanning Tree
191
If you have activated the “MRP Compatibility” function, the device displays
the “Information” frame with additional information on MRP compatibility:
Figure 44: Dialog Spanning Tree, Global
Parameter Meaning Possible Values Default Setting
Information If you have activated the MRP
compatibility (RSTP over MRP) and one of
the participating devices has detected a
configuration problem, the device displays
“Conflict with bridge pppp /
mm mm mm mm mm”. During normal
operation, this field is empty.
Message with bridge
ID or empty.
-
Table 84: Global Spanning Tree settings, Information frame