Basic Settings
30
1.4
Port Configuration
RM Web
Release
6.0
07/2010
Note: The active automatic configuration has priority over the manual
configuration.
Note: If you are using link aggregation, pay attention to its configuration (see
on page 158 “Link Aggregation“).
Note: When you are using a redundancy function, you deactivate the flow
control on the participating ports. Default setting: flow control deactivated
globally and activated on all ports.
If the flow control and the redundancy function are active at the same time,
there is a risk of the redundancy failing.
Note: The following settings are required for the ring ports in a HIPER-Ring:
When you switch the DIP switch for the ring ports, the device sets the
required settings for the ring ports in the configuration table. The port, which
has been switched from a ring port to a normal port, is given the settings
Autonegotiation (automatic configuration) on and Port on. The settings
remain changeable for all ports.
Port Type Bit Rate Autonegotiation
(Automatic Configuration)
Port Setting Duplex
Mode
Optical all off on full
TX 100 Mbit/s off on full
TX 1000 Mbit/s on on -
Table 2: Port Settings for Ring Ports