Page #77 background image
Time
RM Web L3E
Release
6.0
07/2010
3.2
PTP (IEEE 1588)
77
Bottom
synchronization
threshold [ns]
Bottom PTP synchronization
threshold value, specified in
nanoseconds. If the result of
(reference time - local time) is lower
than the value of the bottom PTP
synchronization threshold, then the
local clock is deemed as
synchronous with the reference
clock.
0-999.999.999 30
Top
synchronization
threshold [ns]
Top PTP synchronization threshold
value, specified in nanoseconds. If
the result of (reference time - local
time) is greater than the value of the
top PTP synchronization threshold,
then the local clock is deemed as
not being synchronous with the
reference clock.
31-1.000.000.000 5000
Parameter Meaning Possible Values Default Setting
Is synchronized Local clock synchronized with
reference clock; compare Bottom
synchronization threshold
and Top synchronization
threshold.
true
false
Max Offset
absolute [ns]
Total deviation of the local clock
from the reference clock in
nanoseconds since the local clock
was last reset. The local clock is
reset with “Reinitialize” in this dialog
or by resetting the device.
Table 17: IEEE 1588/PTPStatus
Parameter Meaning Possible Values Default Setting
Table 16: Configuration IEEE 1588/PTP

Table of Contents

Other manuals for Hirschmann MACH 4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 4000 and is the answer not in the manual?

Hirschmann MACH 4000 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 4000
CategoryNetwork Router
LanguageEnglish

Related product manuals