Table 4-18 Guideline of initialization
RAID level Capacity of a disk array Rebuilding time
RAID 1 300GB (SAS: 300GB HDD x 2) Approximately 40 minutes
200GB (SAS: 200GB SSD x 2) Approximately 10 minutes
RAID 5 600GB (SAS: 300GB HDD x 3) Approximately 40 minutes
400GB (SAS: 200GB SSD x 3) Approximately 10 minutes
RAID 6 600GB (SAS: 300GB HDD x 4) Approximately 40 minutes
400GB (SAS: 200GB SSD x 4) Approximately 10 minutes
RAID 10 600GB (SAS: 300GB HDD x 4) Approximately 40 minutes
400GB (SAS: 200GB SSD x 4) Approximately 10 minutes
Tip: The rebuilding time is proportional to the capacity of a disk array.
5. When rebuilding is completed to 100%, click Home.
6. The window returns to the main menu.
MegaRAID WebBIOS for storage expansion blades
4-71
Hitachi Compute Blade 500 Series EFI User's Guide