Change Controller Properties: disk array controller settings
On this window, you can configure disk array controller hardware
configuration.
1. Select Controller Management from Configuration Options window, and
press Enter
.
2. Controller Management window appears. Select Change Controller
Properties, and press Enter.
3. Controller Management > View Change Controller Properties menu
appears.
The following table shows description of items in the window.
Table 6-7 Change Controller Properties menu items
Menu items Description Reference
Apply Changes Applies the setting change. -
Set Boot Device Uses as a boot drive.
Sets virtual drives.
Changing boot priority in
virtual drives on page 6-40
Rebuild Rate Rebuild priority 0 to 100/[<<30>>]
Background Initialization
(BGI) Rate
Background initialization
priority
0 to 100/[<<30>>]
Consistency Check Rate Consistency check priority 0 to 100/[<<30>>]
Apply Changes Applies the setting change. -
Manage Virtual Drive Properties: virtual drive information view
On this window, you can show the virtual drive information.
1. Select Virtual Drive Management from Configuration Options window,
and press Enter.
2. Virtual Drive Management window appears. Select Manage Virtual Drive
Properties, and press Enter.
3. Virtual Drive Management > Manage Virtual Drive Properties menu
appears. Select Select Virtual Drive, and press Enter.