Menu items View/description Value/view/reference
Shield State Supported Status of diagnostics for
physical drives of the disk
array controller
Yes
NVSRAM Size (MB) NVSRAM Size 32
Metadata Size (MB) Metadata Size 512
Minimum Strip Size Minimum Strip Size 64 KB
Maximum Strip Size Maximum Strip Size 64 KB
CacheCade – SSD
Caching
CacheCade setting Disabled
Write Cache Capable Write Cache setting No
Configured Cache Size
(GB)
Current cache size (GB) 0
Maximum Allowed
Cache Size
(GB)
Maximum Allowed Cache Size
(GB)
0
Replace Drive Copyback Enabled (valid) /
[<<Disabled (invalid)>>]
Replace Drive on
SMART Error
SMART copyback Enabled (valid) /
[<<Disabled (invalid)>>]
Rebuild Rate Priority of rebuilding process 0 to 100 / [<<30>>]
Background
Initialization
(BGI) Rate
Priority of background
initialization
0 to 100 / [<<30>>]
Consistency Check Rate Priority of consistency check 0 to 100 / [<<30>>]
Reconstruction Rate Priority of capacity expansion 0 to 100 / [<<30>>]
Controller BIOS Disk array controller BIOS is
enabled.
[<<Enabled (valid)>>] /
Disabled (invalid)
Coercion Mode Set a physical hard disk in
creating virtual drives
[<<None (All capacity
used)>>] / 128 MB
(Multiples of 128 MB
used) / 1GB (Multiples of 1
GB used)
SMART Polling Sets an interval of SMART
polling
0 to 65535/ [<<600>>]
Alarm Control Sounds the disk array
controller buzzer when a
connected device fails.
Enabled (valid) /
[<<Disabled (invalid)>>]
Boot Error Handling Error notice of the disk array
controller at the system boot
Safe mode (Boot in safe
mode) / [Ignoreerrors
(Ignores the error to
continue running)]
(Recommendable value
without using SAS 3004
SAS 3004 iMR ROMB Configuration Utility
5-23
Hitachi Compute Blade 500 Series EFI User's Guide