Menu items Description Value/reference
Virtual Drive Name Sets virtual drive name. Name any name.
Virtual Drive Size Virtual drive size Set any value.
Virtual Drive Size Unit Sets virtual drive size unit. KB / MB / [<<GB>>]
Strip Size Strip size 64 KB
Access Policy Access policy [<<Read/Write>>] / Read
Only / Blocked
Drive Cache Sets drive cache of the
physical drive.
Enable / [<<Disable>>]/
Unchanged
Disable Background
Initialization
Executes Background
Initialization
[<<Yes>>] / No
Default Initialization Initialization after creating
virtual drives
Full / Fast / [<<No>>]
11. When settings are complete, select Save Configuration and press
Enter.
12. The following Warning appears.
Select Confirm and press Space.