EasyManua.ls Logo

Hitachi Compute Blade 500 Series - Page 356

Hitachi Compute Blade 500 Series
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Conditions to generate foreign configuration
A physical drive failed and could not be recognized. Then the physical drive has been
restored to be recognized.
A physical drive, used in another device with a specific virtual drive configuration, is
used.
Follow the steps below to check the configuration.
1. Select Configuration Management from the Main Menu, and press
Enter.
2. Configuration Management window appears.
Select Manage Foreign Configuration and press Enter.
3. Manage Foreign Configuration window appears.
Select Preview Foreign Configuration and press Enter.
4. Configuration is displayed.
5-48
SAS 3004 iMR ROMB Configuration Utility
Hitachi Compute Blade 500 Series EFI User's Guide

Table of Contents

Other manuals for Hitachi Compute Blade 500 Series

Related product manuals