Message Description
Press any key to continue, or C to
load the configuration utility.
a. Enter a character, and then press the Enter
key.
The following message appears: Critical
Message handling completed. Please exit.
b. Press the ESC key.
The selection window appears.
c. Press the Y key.
System startup continues.
Action 2:
a. Press the C key, and then press the Enter
key.
b. The LSI MegaRAID <HITACHI SAS 3004
iMR ROMB> Configuration Utility restarts.
Action 3:
If this message appeared, contact your reseller
or call maintenance personnel.
The VDs: %s have Rollback active
and corresponding Repository
missing.
If you continue to boot the system
or enter the configuration utility,
these VDs becomes unusable.
Press any key to continue.
Cause:
The disk array controller parameter is incorrect.
Action 1:
a. Enter a character, and then press the Enter
key.
The LSI MegaRAID <HITACHI SAS 3004
iMR ROMB> Configuration Utility restarts.
Action 2:
If this message appeared, contact your reseller
or call maintenance personnel.
Upgrade Key Missing! An upgrade
key was present on a previous
power cycle, but it is not
connected. This can result in
inaccessible data unless it is
addressed.
Reattach the upgrade key and
reboot.
Cause:
The upgrade key is not supported.
Action:
If this message appeared, contact your reseller
or call maintenance personnel.
If this message appeared, the system startup
cannot continue.
Unable to change security to EKMS
as not able to communicate to
EKMS.
If you continue, the drive security
remains to existing security mode.
Please check connection with the
EKMS, reboot the machine to retry
the EKMS or press any key to
continue
Cause:
The hard disk security functionality is not
supported.
Action 1:
a. Enter a character, and then press the Enter
key.
The following message appears: Critical
Message handling completed. Please exit.