HP 8114A
Service Guide
-222
-222
-222
-222
-222
-222
-222
-222
-222
-222
-222
Data out of range
HP-IB message = “LOAD-IMP-RANGE”
Local message = “Output into Load: 0.1 Ohm to
999 kOhm”
Data out of range
HP-IB message = “HIL-VOLT-RANGE”
Local message = “High level: -49.0 V to 50.0
V”
Data out of range
HP-IB message = “HIL-AMP-RANGE”
Local message = “High level: -1.998 A to 2.000 A”
Data out of range
HP-IB message = “LOL-VOLT-RANGE”
Local message = “Low level: -50.0 V to 49.0
V”
Data out of range
HP-IB message =
“LOL-AMP-RANGE”
Local message = “Low level: -2.000 A to 1.998 A”
Data out of range
HP-IB message =
“HIL-LIM-VOLT-RANGE”
Local message = “High-V Limit: -49.0 V to 50.0
V”
Data out of range
HP-IB message =
“LOL-LIM-VOLT-RANGE”
Local message = “Low-V Limit: -50.0 V to 49.0
V”
Data out of range
HP-IB message =
“HIL-LIM-AMP-RANGE”
Local message = “High-A Limit: -1.998 A to 2.000
A”
Data
out
of range
HP-IB message =
“LOL...LIM-AMP-RANGE”
Local message = “Low-A Limit: -2.000 A to 1.998
A”
Data out of range
HP-IB message = “Trigger too fast
-
will skip
bursts”
Local message = “Trigger too fast
-
will skip
bursts”
Data out of range
HP-IB message = “Width
>
Period”
Local message = “Width
>
Period”
Troubleshooting 5-27