Common print stop test timing millisecond (ms) stops
600 ms: The page has passed the registration area and the leading edge is just short of entering the
fuser. The image can be seen on the paper but has not fused. If the defect is visible then the cause might
be the drum, transfer roller, or a roller prior to, or in, the registration area.
1200 ms: The leading edge is about 18mm (0.71 in) into the top output bin. The image has gone through
the fuser. If the defect was not visible prior to the fuser, and is visible after the fuser, then the fuser it is
the likely cause of the print quality defect. Inspect the fuser for damage, debris, or labels stuck to the
fuser. Replace the fuser. Discuss media specications and proper care of the fuser with the customer.
154 Chapter 2 Solve problems ENWW